Volume 3 Issue 4
Jul.  2013
Turn off MathJax
Article Contents
XU Hao, TIAN Zhi-yong, SONG Yong-hui, ZHANG Li-cheng. Performance and Feasibility of ANAMMOX Bio-filter Process for Advanced Treatment of Dry-spun Acrylic Fiber Wastewater[J]. Journal of Environmental Engineering Technology, 2013, 3(4): 286-292. doi: 10.3969/j.issn.1674-991X.2013.04.045
Citation: XU Hao, TIAN Zhi-yong, SONG Yong-hui, ZHANG Li-cheng. Performance and Feasibility of ANAMMOX Bio-filter Process for Advanced Treatment of Dry-spun Acrylic Fiber Wastewater[J]. Journal of Environmental Engineering Technology, 2013, 3(4): 286-292. doi: 10.3969/j.issn.1674-991X.2013.04.045

Performance and Feasibility of ANAMMOX Bio-filter Process for Advanced Treatment of Dry-spun Acrylic Fiber Wastewater

doi: 10.3969/j.issn.1674-991X.2013.04.045
More Information
  • Corresponding author: SONG Yong-hui E-mail: songyh@craes.org.cn
  • Received Date: 2012-12-02
  • Rev Recd Date: 2012-12-24
  • Publish Date: 2013-07-20
  • Aiming at the high ammonia-nitrogen concentration, low biodegradability and non-compliance issues of dry-spun acrylic fiber wastewater, the effluent of third-sedimentation tank was taken as experimental substrate to research the feasibility and performance of ANAMMOX bio-filter process for advanced treatment of dry-spun acrylic fiber wastewater. The results indicated that the ANAMMOX bio-filter had a good denitrification ability of dry-spun acrylic fiber wastewater after 130 days domestication, the effluent ammonia-nitrogen concentration decreased from 184.1-205.3 mg/L to 23.4-30.34 mg/L, and the removal efficiency of ammonia-nitrogen reached 83.5%. The removal efficiency of NO2--N reached up to 93.6%, the removal of NH4+-N and NO2--N efficiencies were close to 1:1 (theoretical value 1:1.32), and the total nitrogen removal load reached 2.36-4.80 kg/(m3/d). However, the effluent concentration of total nitrogen was still as high as 165.9-180.7 mg/L, mainly exiting in the form of refractory organics. In addition, the removal of CODCr with ANAMMOX bio-filter process was confirmed, the removal load reached up to 2.39-2.56 kg/(m3/d), the effluent CODCr decreased from 487.9-532.1 mg/L to 188.6-212.3 mg/L, which could meet the requirement of Class II standard of National Discharge Standard for Petrochemical Industry (GB 8978-1996) in China.

     

  • loading
  • 加载中

Catalog

    通讯作者: 陈斌, bchen63@163.com
    • 1. 

      沈阳化工大学材料科学与工程学院 沈阳 110142

    1. 本站搜索
    2. 百度学术搜索
    3. 万方数据库搜索
    4. CNKI搜索

    Article Metrics

    Article Views(2543) PDF Downloads(984) Cited by()
    Proportional views
    Related

    /

    DownLoad:  Full-Size Img  PowerPoint
    Return
    Return