Abstract:
To analyze the purifying effect of on-stream detention pond (OSDP) on polluted urban river in high temperature period (18-30 ℃), medithermal period (9-25 ℃) and hypothermic phase (5-17 ℃), three kinds of on-stream detention ponds were adopted and monitored. The retention time (HRT) of OSDP-A with a narrow channel and a fast flowing rate is 0.5 d, the HRT of OSDP-B with a wide channel and a slow flowing rate is about 2 d, the HRT of OSDP-C possessing a bank wetland and fast flowing rate is about 0.3 d. Under different temperature conditions, the removal efficiency on different pollutants indexes of 3 kinds of natural OSDPs was compared. The results shown that in the OSDP-A, the removal efficiency of TN can reached the highest, about 12%. The OSDP-B presented the best removal capability for TP with its removal efficiency as much as 45%. However, the highest removal efficiencies of COD
Cr were observed in OSDP-C, being 37%. The effects of various kinds of OSDP on the removal of nitrogen, phosphorus and organic contamination were observed, and the removal rates of TP and COD
Cr were better than TN in general. Additionally, with water temperature increasing, the treat capability of different OSDPs kept relative stable; while with water temperature decreasing, their removal efficiencies presented unstable.